Features
- Yaskawa inverter G7 is the 3-level control method solves micro surge problem for 400V class drives.
- Open Loop vector: over 150 % torque at 0.3 Hz. Flux Loop vector: 150% at 0 Hz
- Removable control circuit terminals and cooling fan.
- Various application software (cranes, hoist, energy-saving control, and more)
- Yaskawa inverter G7 has auto-tuning function.
Specifications
Application of Yaskawa inverter G7 |
Paper manufacturing machines, Transportation, Fans and Pumps, HVAC, Metal machining tools, public facilities, medical equipment, living enviroment, food processing machines, and more. |
Power supply |
3P, 200/208/220/230/240 Vac, 380/400/415/440/460/480 Vac (− 15% to +10%) 50/60 Hz (± 5%) |
Rated capacity |
0.4-110 kW (200 V), 0.4-300 kW (400 V) |
Rated current |
3.2-415 A (200 V), 1.8-605 A (400 V) |
Output frequency range |
0.01 to 400 Hz |
Starting Torque |
150 % at 0.3 Hz (open loop vector control 2) 150 % at 0 min-1 (vector control with PG) |
Overload current rating |
150 % rated ouput current for 1 minute 200 % rated output current for 0.5s |
Control Method |
Sine wave PWM (Vector with PG, open loop vector 1, open loop vector 2, V/f, V/f with PG) |
Braking unit |
All models up to 30 kW are equipped with a brak -ing transistor for even more powerful braking op -tions by just adding a braking resistor. |
Input |
Sequence input, Analog input |
Ouput |
Photo-coupler output, relay output, analog monitor output, pulse I/O |
Protection Function |
Motor overload protection, Instantaneous overcurrent, Fuse Protection, overload, overvoltage, undervoltage, momentary power loss, fin overheat, stall prevention, ground fault, power charge indication |
Main Control Functions |
Momentary power loss restart, Speed search, overtorque detection, torque limit, 17-step speed operation (max.), Accel/decel time changeover, S-curve accel/decel, 3-wire sequence, auto-tuning (dynamic, static), DWELL, Cooling fan ON/OFF, Slip compensation, Torque compensation, Jump frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID control (with sleep function), Energy-savng control, MEMOBUS communication (RS-485/422 max. 19.2 kbps), Fault retry, Constant copy, Droop control, Torque control, Speed/torque control changeover, etc. |
Communication |
RS-422 /485 (MEMOBUS/Modbus at 115 .2 kbps) standard on all models. |
Peripheral Devices and Options |
LCD Operator, AC Reactor, DC Reactor, Braking Unit, Braking Resistor, noise filter... |
Degree of protection |
IP 00 open-chassis, IP 20 NEMA Type 1 enclosure |
Ordering information
Dimensions