Mitsubishi Inverter FR-F740 series 

Mitsubishi Inverter FR-F740 series
Manufacturer: MITSUBISHI
Item Status: Contact us
 9.513

Series: Mitsubishi Inverter FR-F740 series

Features

- Mitsubishi Inverter FR-F740 series more energy savings

- Ideal for fans and pump.

- Long life and simple maintenance.

- Reduction of electromagnetic noises (EMC filter)

- Simple operation.

- Enhanced network.

- Mitsubishi Inverter FR-F740 series Global compliance

- Enhanced PID function

- Tackling Power Loss and Recovery.

- Mitsubishi Inverter FR-F740 series, Energy Saving, Environmental Features, Safety.

Specifications

Application of inverter

Mitsubishi FR-F740

ND: Fans, Pumps, HVAC
HD: Crane, hoist, conveyor, compressor, punching press, winder, tool machine,…

Power supply

3P, 380 to 480Vac 50/60 Hz

Rated capacity

0.75-560 kW

Rated current

2.1-1094 A (400V)

Output frequency range

0.5 to 400 Hz

Starting Torque

120% (3Hz) when set to simple magnetic flux vector control and slip compensation

Overload current rating

120% 60s, 150% 3s (inverse time characteristics)

Control Method

V/f Control, V/f Control with PG, Open Loop Vector Control, Closed Loop Vector Control, Open Loop Vector
Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM

Braking unit

-

Input

Multi-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, External-NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock

Ouput

Inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm1, heatsink overheat pre-alarm, deceleration at an instantaneous power failure, PID control activated, PID output interruption, safety monitor output, safety monitor output 2, during retry, life alarm, current average value monitor, remote output, alarm output, fault output, fault output 3, and maintenance timer alarm

Protection Function

Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat, input phase loss 3 4, output side earth (ground) fault overcurrent at start3, output phase loss, externalthermal relay operation 3, PTC thermistor operation3, parameter error, PU disconnection, retry count excess 3, CPU fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value exceeded 3, safety circuit fault

Main Control Functions

Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU

Communication

PU connector

RS-485

Peripheral Devices and Options

Parameter unit (8 languages), Enclosure surface operation panel, Parameter unit connection cable, AC reactor, DC reactor, EMC Directive compliant noise filter, EMC compliant EMC filter installation attachment, Radio noise filter, Line noise filter, Brake resistor, High-duty brake resistor, Brake unit, Resistor unit, Discharging resistor, Power regeneration common converter Stand-alone reactor dedicated for the FR-CV, High power factor converter, Manual controller, DC tach. Follower, Three speed selector, Motorized speed setter, Speed detector, Master controller, Soft starter, Deviation detector, Preamplifier, Pilot generator, Deviation sensor, Frequency setting potentiometer, Analog frequency meter, Calibration resistor, FR Configurator SW3(VFD setup software)

Degree of protection

IP 00 open -chassis, IP 20 NEMA Type 1 enclosure

Ordering information

Ordering information Mitsubishi Inverter FR-F740 series

Ordering information Mitsubishi Inverter FR-F740 series

Dimension

 Dimension Mitsubishi Inverter FR-F740 series

Dimension Mitsubishi Inverter FR-F740 series

Dimension Mitsubishi Inverter FR-F740 series

Dimension Mitsubishi Inverter FR-F740 series

Dimension Mitsubishi Inverter FR-F740 series


Connection

Connection Mitsubishi Inverter FR-F740 series

Connection Mitsubishi Inverter FR-F740 series

 
 
 

Bài viết bạn nên xem 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Document of Mitsubishi Inverter FR-F740 series

Comment about product
Loading  Processing, please wait ...
Contact us now

 Bao An Automation

Bao An Technique Service Joint Stock Company
Address: 3A Ly Tu Trong, Minh Khai, Hong Bang, Hai Phong, Viet Nam
Office 1: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Office 2: 3/38, Chu Huy Man, Phuc Dong, Long Bien, Ha Noi, Viet Nam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Phone: (+84) 2253 79 78 79, Hotline: (+84) 989 465 256
Tax code: 0200682529 - Date: 31/07/2006
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 9 -  Total visited: 91.192.547
Chat hỗ trợ