Network Communication Protocols for Yaskawa Inverter

DeviceNet (Device Network), is a protocol that is owned and regulated by the ODVA (Open Device Vendors Association). This protocol is an RS-485 based fieldbus network capable of multi drop nodes. It is a widely popular fieldbus network that is complemented by its Ethernet counterpart, EtherNet/IP.

 

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

SI-N3

CN5-A

V1000
V1000-4X

SI-N3/V

CN5

G7 Drive

CM012

2CN

 

EtherNet/IP is a popular, globally-used network capable of hundreds of nodes on one network.

Drive Series

Option

Drive Connection

A1000
A1000 Configured
U1000 Industrial
P1000
P1000 Configured
P1000 Bypass
D1000
R1000

SI-EN3 (Single)
SI-EN3D (Dual)

CN5-A

     

V1000
V1000-4X

SI-EN3/V (Single)
SI-EN3D/V (Dual)

CN5

G7
G7 Configured

CM092

2CN

 

EtherCAT is an Ethernet-based protocol. The EtherCAT option allows the user to operate the drive, monitor the status, and change parameters from an EtherCAT master device.

 

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

SI-ES3

CN5-A

V1000
V1000-4X

SI-ES3/V

CN5

 
 

This option is designed for connecting a drive to a field network using the MECHATROLINK protocol. The MECHATROLINK-II option allows the user to operate the drive, monitor the status, and change parameters from a MECHATROLINK master device at a communication speed up to 10Mbps.

Drive Series

Option

Drive Connection

A1000
P1000
U1000 MATRIX

SI-T3

CN5-A

V1000
V1000-4X

SI-T3/V

CN5

 

This option is designed for connecting a drive to a field network using the MECHATROLINK protocol. The MECHATROLINK-III option allows the user to operate the drive, monitor the status, and change parameters from a MECHATROLINK master device at a communication speed up to 10Mbps.

Drive Series

Option

Drive Connection

A1000
U1000 Industrial

SI-ET3

CN5-A

V1000

SI-ET3/V

CN5

 

Modbus TCP/IP is an Ethernet-based network that uses the TCP and IP protocols to transfer to and from devices. This provides a very simple and easy means to send and receive data from your devices.

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

SI-EM3 (Single)
SI-EM3D (Dual)

CN5-A

V1000
V1000-4X

SI-EM3/V (Single
SI-EM3D/V (Dual)

CN5

G7 Drive

CM090

2CN

 

Modbus RTU is a RS-485 widely used network protocol. This network is capabile of multiple nodes and is complimented by its Ethernet-based counterpart, Modbus TCP/IP.

RS-232

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

Embedded

CN2-2

J1000

SI-232/J

CN5

G7 Drive

Embedded

CN1

RS-485

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

Embedded

Terminal Strip

J1000

SI-485/J

CN5

G7 Drive

Embedded

Terminal Strip

 

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

SI-P3

CN5-A

V1000
V1000-4X

SI-P3/V

CN5

G7 Drive

CM061

2CN

 

PROFINET (PROcess FIeld NETwork) is a widely-used Ethernet-based fieldbus network protocol, capable of hundreds of nodes on the network.

Drive Series

Option

Drive Connection

A1000
P1000
U1000 Industrial

SI-EP3

CN5-A

V1000
V1000-4X

SI-EP3/V

CN5

 

 13.246      16/06/2022
  Maybe you are interested

 Bao An Automation

Bao An Technique Service Joint Stock Company
Haiphong Office and Warehouse: Van Tra B project area, An Dong, An Duong Dist., Haiphong City, Vietnam
Hanoi Office and Warehouse: No. 3/38, Chu Huy Man Str., Phuc Dong Ward, Long Bien Dist., Hanoi City, Vietnam
Ho Chi Minh Office and Warehouse: No. 204, No Trang Long Str., Ward 12, Binh Thanh Dist., Ho Chi Minh City, Vietnam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Hotline South: (+84)989 465 256
Hotline North: (+84)936 862 799
Tax code: 0200682529 - Date: 31/07/2006
Invoice address: 3A Ly Tu Trong Street, Minh Khai Ward, Hong Bang District, Hai Phong City, Viet Nam
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 20 -  Total visited: 121.081.195
Chat hỗ trợ