Bao An would like to summarize a list of error codes of the SEHAN series screw gun to help customers easily understand the cause of the error, and easily take the initiative to fix them:
Code |
Error |
Description |
Quick fix |
100 |
Air pressure |
The air pressure supplied to the controller is lower / 5% higher than the manufacturer's required parameters |
Press reset button or set restart parameter (P83= 77) |
101 |
Screw gun sensor |
Not receiving sensor signal from screw gun |
Press the reset button |
110 |
Overload current AMP |
Current overload on the AMP . board |
Auto reset after 1s |
111 |
Overload SMPS |
Overload protection due to over 8A in power supply SMPS |
Power off, and back on after 1 minute |
112 |
Overload amperage |
Through 5A after more than 1s |
Auto reset after 1s |
113 |
The gun is overheated |
Over 80°C in a screw gun |
Auto reset after temperature below 80°C |
114 |
Over speed |
The rotation speed is over the set value.Check the connection cable |
Auto reset after 1s |
115 |
Circuit board error |
Wrong EEP-ROM information in the controller. Check for EEP-ROM damage or communication failure |
Press the reset button |
116 |
Force calibration error |
Calibrate the force beyond the required value of the gun. EEP-ROM damage check |
Press the reset button |
117 |
Connected device is not compatible |
The gun model is not compatible with the controller. |
Press the reset button |
118 |
Engine failure |
Start gun motor not running |
Request for repair/replacement |
Code |
Error |
Description |
Quick fix |
200 |
Error getting parameter |
Error receiving wrong parameters from EEP-ROM of screw gun |
Press the reset button |
201 |
Parameter check error |
Parameter read is wrong according to checksum procedure |
Press the reset button |
202 |
Initialization error |
Initialization error on boot |
Power Off OffàOn |
203 |
Connection errors |
Failed connection with screw gun |
Automatically reset after the set time |
204 |
Timeout error |
Connection time more than 1s |
Automatically reset after the set time |
205 |
Parameter setting error |
Parameters in the controller error when connecting the screw gun |
Reset parameter setting (P83 = 77) |
Code |
Error |
Description |
Quick fix |
300 |
Screw loosening time limit |
Bypass the loosening time at parameter P66 |
Automatically reset after the set time |
301 |
Beyond the rotation |
Exceeded the rotation specified in P21~28 |
Automatically reset after the set time |
302 |
Screw tightening time limit |
Exceeded screw tightening time in parameter P67 |
Automatically reset after the set time |
303 |
Engine stop time limit |
Exceeded motor stop time in parameter P68 |
Automatically reset after the set time |
304 |
Screw count time over |
Over the screw count time in parameter P77 |
Automatically reset after the set time |
305 |
Missing screw |
When the screw tightening process has not tightened enough of the installed screws, a message will appear |
Auto reset after set time or press reset button |
306 |
Do not tighten the screw |
When the screw gun stops without the minimum rotation according to the set parameter P31~38 |
Automatically reset after time |
307 |
Tight start-up time |
The tightening force is too early compared to the time in parameter P31~38 |
Automatically reset after time |
308 |
Tightening force NGO |
The set tightening force is outside the set force range |
Automatically reset after time |
Error code |
Resovle problem |
100 |
Malfunction of air pressure The outlet air pressure exceeds ±5% of the manufacturer's tolerance or there is a leak in the air line. Reset by pressing the Reset button. -> If there is a gas leak there will be a buzzing sound of the internal regulator remote controll.Turn off the power and check all the air hoses connected to the controller. -> If there is a compressed air leak from the regulator to the controller, check the compressed air via connector, cable and actuator clutch. The outlet pressurized air is closed in Jog and Parameter mode |
101 |
Sensor sensor error The controller cannot read the sensor signal from the screw gun -> Check the quality of cables and connectors -> Wiring inside the controller |
110 |
Current overload on the AMP . board -> Turn off the controller for a minute and turn it back on |
111 |
SMPS overload error There is excess current in the system. -> Check for any damage to the mechanical load. -> Check engine quality. |
112 |
Overload amperage -> Over 5A current for 1 second or more, exceeding the requirement |
113 |
Engine overheating The temperature of the motor above 80℃causes the motor to not work. -> Turn off the controller for a while to reduce overheating |
117 |
Run time limit The controller will automatically stop at the set runtime limit. -> Set initial value to 10 seconds. |
200 |
Screw gun data error The data in the EEP-ROM of the screw gun is not verified. -> Keep the controller powered off when the screw gun is connected to the controller.ROM data may be lost. |
202 |
Connection failed error The controller cannot connect to the screw gun when it turns on ->Try turning on the power again after turning it off. |
204 |
Connection error more than 1 second Check the connection of the cable between the screw gun and the controller |
303 |
Engine stop time limit ->To prevent the motor from overheating, it should stop immediately after 1 second from locking the motor. |
To be able to choose the right screw gun product as well as ensure the genuine product, please contact us via baoan@baoanjsc.com.vn . With the motto of professional and dedicated work, Bao An Automation is always committed to bringing customers the best quality products at reasonable prices and ensuring on-time delivery.
Contact for detailed advice: