Type |
Digital controller |
Display type |
LCD display |
Display digits |
4 |
Character height (Present value) |
8.5mm |
Power supply voltage |
24VAC, 24VDC |
Control mode |
Cooling control, Heating control |
Control method |
2-PID control, ON-OFF control |
Number of channel |
1 |
Temperature range |
0...100ºC, 0...120ºC, 0...1300ºC, 0...165ºC, 0...1700ºC, 0...1800ºC, 0...2300ºC, 0...260ºC, 0...90ºC, -100...850ºC, -199.9...400ºC, -199.9...500ºC, -20...400ºC, -20...500ºC, -200...1300ºC, -200...400ºC, -200...850ºC, -200...600ºC |
Number of sensor input |
1 |
Sensor input type |
B, C, E, Infrared temperature sensor, J, JPt 100Ohm, K, L, N, PL2, Pt 100Ohm, R, S, T, U, W, 0...10VDC, 0...20mADC, 0...5VDC, 1...5VDC, 4...20mADC |
Number of control output |
1 |
Control output type |
Relay output |
Number of auxiliary output |
2 |
Auxiliary output type |
Relay output |
Number of event input |
1 |
Event input type |
Contact input, Non-contact input |
CT input |
Yes |
Communication |
No |
Function |
Manual output, Heating/cooling control, Loop burnout alarm, SP ramp, Other alarm functions, Heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, Input digital filter, Self tuning, Robust tuning, PV input shift, Run/stop, Protection functions, Extraction of square root, MV change rate limit, Logic operations, Temperature status display, Simple programming, Moving average of input value, Display brightness setting, Simple transfer output, Work bit message |
Mounting method |
DIN rail mounting |
Panel cutout |
W22.7xH92mm |
Connection method |
Screw terminals |
Ambient temperature (with no icing) |
-10...55°C, -25...70°C |
Ambient humidity (with no condensation) |
25...85%, 90% or less |
Approx. weight |
80g |
Overall width |
22.5mm |
Overall height |
96mm |
Overall depth |
85mm |
Degree of protection |
IP00, IP20, IP66 |
Representative standard |
CE, CSA, KC, UL |
Standard accessories |
No |
Separately accessories |
Communications conversion cable: E58-CIFQ2-E, Current transformers: E54-CT1L, Current transformers: E54-CT3L, CX-thermo support software: EST2-2C-MV4, DIN track mounting adapter: Y92F-52, DIN tracks: PFP-100N, DIN tracks: PFP-50N, Draw-out jig: Y92F-58, End cover: Y92F-54, Front connecting socket: P2CF-08, Front connecting socket: P2CF-08-E, Mounting brackets: Y92H-10, Communication converter: SCM-38I, Sockets: P3GA-11, Terminal cover: E53-COV16, Communication converter: SCM-US48I, Current transformer: CSTC-E80PP, Waterproof cover: Y92A-48N |