Type |
Safety light curtains / safety light barriers / safety multi-light beams |
Sensing method |
Through-beam (Full set) |
Max. sensing distance |
17m |
Protective height |
640mm |
Number of optical axis |
32 |
Optical axis pitch |
20mm |
Dimension of standard sensing object |
D25mm |
Standard sensing object |
Opaque |
Power supply voltage |
24VDC |
Input type |
Contact |
Input functions |
External device monitoring (EDM) input, Test input (External test) |
Output type |
PNP |
Operation mode |
Light On |
Light source (wavelength) |
Infrared LED (870 nm) |
Response time |
190ms, 90ms |
Protection function |
Reverse polarity protection, Short-circuit protection |
Function |
Cascade connection, Reduced resolution, Self-test (Test function), Scan code selection, Auxiliary output |
Safety standards |
Classification: type B, HFT, Performance level (PL)/ safety category: PL e/category 4, PFHD, Proof test interval TM: every 20 years, SFF |
Communication |
No |
Case material |
Aluminum alloy |
Connection method |
Pre-wire connetor |
Cable length |
0.3m |
Mounting method |
Backside mounting, Side-mount bracket |
Operation ambient |
Oil-resistance |
Ambient illumination |
Sunlight: 10,000 Ix max. |
Ambient temperature |
-10...55°C |
Ambient humidity |
35...85% |
Approx. net weight |
1.7kg |
Overall width |
31.4mm |
Overall height |
640mm |
Overall depth |
38mm |
Degree of protection |
IP65, IP67 |
Representative standard |
CE, TUV, UL |
Standard accessories |
Standard fixed bracket |
Separately accessories |
Bluetooth communication unit: F39-BT, Double-ended cable: F39-JD10B, Double-ended cable: F39-JD15B, Double-ended cable: F39-JD1B, Double-ended cable: F39-JD20B, Double-ended cable: F39-JD3B, Double-ended cable: F39-JD5B, Double-ended cable: F39-JD7B, Double-ended cable: F39-JDR5B, End cap: F39-CNM, Interface unit: F39-GIF-1, Lamp and bluetooth communication unit: F39-BTLP, Lamp: F39-LP, Laser pointer for F3SG-R: F39-PTG, Reduced wiring connector: F39-CN5, Sensor mounting brackets: F39-LGRA, Sensor mounting brackets: F39-LGRTB, Sensor mounting brackets: F39-LGRTB-2, Sensor mounting brackets: F39-LGRTB-3, Single-ended cable: F39-JD3A, Single-ended cable: F39-JD3RA-D, Single-ended cable: F39-JD3RA-L, Single-ended cable: F39-JD7RA-D, Single-ended cable: F39-JD7RA-L, Test rod: F39-TRD25, Cable for reduce wiring: F39-JD0307BA, Cable for reduce wiring: F39-JD1010BA, Cascading cable: F39-JGR2WTS, Single-ended cable: F39-JD20A, Single-ended cable: F39-JD15A, Single-ended cable: F39-JD10A, Single-ended cable: F39-JD7A, Cable for reduce wiring: F39-JD1003BA, Cable for reduce wiring: F39-JD0510BA, Cable for reduce wiring: F39-JD0507BA, Cable for reduce wiring: F39-JD1007BA, Cable for reduce wiring: F39-JD0503BA, Cable for reduce wiring: F39-JD0310BA |