Display |
LCD, 4 (4199 digits) |
AC current measurement range |
41,99 ~ 1000 A, 3 measuring strip(40 ~1kHz, Average rectified), accuracy: ±1,5 % rdg. ±5 dgt |
DC voltage measurement range |
4,199 V ~ 600 V, 4 measuring strip, accuracy: ±2,3 % rdg. ±8dgt |
AC voltage measurement range |
4,199 V ~ 600 V, 4 measuring strip(50 ~ 500 Hz, Average rectified), accuracy: ±2,3 % rdg. ±8 dgt |
Peak coefficient |
≤2,5 (1,5 f.s of measuring strip) |
Resistance measurement range |
419,9 Ω ~ 41,99 MΩ, 6 measuring strip, accuracy: ±2 % rdg. ±4 dgt |
Function |
Measurment of circuits (50 Ω ±40 Ω), data retention, energy saving |
Power supply |
Pin type pin lithium (CR2032) ×1,continuous use 50 hours |
Clamp head diameter |
φ 33 mm |
Size anh volume |
W57x H175x D16,10 |
Standards |
CE CAT III 600 V (Current) CAT III 300 V (Voltage) CAT II 600 V (Voltage) |
Accessorise |
Measuring stick 9208 ×1, case 9398 ×1 |