Features
- RKC Temperature Controller RB series has easy-to-read with large 11-segment LCD display
- The depth of 60mm
- Sampling 0.25 sec
- RKC Temperature Controller RB is Brilliant II PID control
- Start-up tuning and Autotuning
- Application of RKC temperature controller RB: Use to control temperature in plastic machines (extrudes, injection machine, etc), electric furnaces, semiconductor, food processing, environmental chambers and many others.
Specifications
Dimensions |
H48xW48xD60, H72xW72xD60, H48xW96xD60, H96xW48xD60, H96xW96xD63 |
Display |
11- Segment (PV: red, SV: green) LED method |
Power supply |
100 – 240 VAC, 24 VAC (50/60Hz), 24VDC |
Input |
Thermocouple: K, J, R, S, B, E, T, N, PLII, W5Re/W26Re RTD: Pt100, JPt100 Voltage: 0 to 1 V DC, 0 to 5 V DC, 1 to 5 V DC, 0 to 10 V DC Current: 0 to 20 mA DC, 4 to 20 mA DC Digital (Optional): 2 points (DI1, DI2) |
Output |
Control output: - Relay: 250VAC 3A - Voltage pulse: 0/12 VDC - SSR (Triac): 0.5A - Current: DC 4-20mA, DC 0-20mA (load 500Ω Max.) - Voltage: 0 to 5V DC, 1 to 5V DC, 0 to 10V DC - Open collector: Sink type
Event/Alarm output: Up to 4 points (Event 1 to 4) (RB100 : Up to 3 points, Heat/Cool type : Up to 2 points) |
Sampling period |
0.25 s |
Control method |
PID control, Heat/Cool type PID control |
Functions |
Auto tuning Heat/cool control Timer Function Hold/Re-hold action Control loop break alarm (LBA) Heater break alarm (HBA) |
Communication |
RS485 |
Connections |
Screw terminal block |
Mounting method |
Flush mounting, surface mounting |
Accessories |
Current transformer for heater break alarm (HBA), 250 Ω shunt resistor for current input, Terminal Cover, Front Cover |
Degree of protection |
IP 66 |
Standards |
CE, UL |