Features
- Omrons Temperature Controller E5CN is indication Accuracy
+ Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
+ Pt input: ±0.2% of PV (previous models: ±0.5%)
+ Analog input: ±0.2% FS (previous models: ±0.5%)
- New E5CN-U Models (Plug-in Models) with analog inputs and current outputs.
- Omrons Temperature Controller E5CN has a PV/SV-status display function can be set to automatically alternate between displaying
the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.- Multi-input function: (13 kinds of multi-input selection function): Temperature
sensor, voltage and current selection function.
- In temperature controller E5CN, Preventive maintenance for relays in the Temperature. Controller using a Control Output ON/OFF
Counter.
- Application of temperature controller E5CN: Use to control temperature in heat oven, plastic molding machine, wood, paper
industries, chemicals, electronic components, food processing.
Specifications
Dimensions |
H48xW48 |
Display |
7 Segment(PV: red, SV: green) LED method |
Power supply |
100-240VAC 50/60Hz, 24VAC/VDC, 85% to 110% of rated supply voltage |
Input |
RTD: Pt100 or JPt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Analog: 4 to 20 mA; 0 to 20 mA; 0 to 50 mV; 1 to 5 V, 0 to 5 V, or 0 to 10 V |
Output |
Control output: - Relay: SPST-NO, 250 VAC, 3 A - SSR: 12 VDC ±15% (PNP) - Current: 4 to 20 mA DC/0 to 20 mA DC (load 600Ω Max.) - Long-life relay output (hybrid): SPST-NO, 250 VAC, 3 A
Sub output: - EVENT1: SPST-NO, 250 VAC, 3 A - EVENT 2: SPST-NO, 250 VAC, 3 A |
Sampling period |
250 ms |
Control method |
ON/OFF control or 2-PID control (with auto-tuning) |
Functions |
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure and heater overcurrent detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment |
Communication |
RS485 |
Connections |
Screw terminal block, 11-pin socket |
Mounting method |
Flush mounting, surface mounting |
Accessories |
USB-Serial Conversion Cable, Terminal Cover, Waterproof Packing, Current Transformers (CTs), Adapter, DIN Track Mounting Adapter, Sockets (for Plug-in Models), Front cover, CX-Thermo Support Software (Order Separately) |
Degree of protection |
IP66, Rear case: IP20, Terminals: IP00 |
Standards |
CSA, UL, EN |