Type |
Multimeter |
Display type |
Digital |
Display digits |
4 |
Display features |
LCD display |
Measured parameter |
AC current, DC current, AC voltage, DC voltage, Resistance, Capacitance, Frequency, Diode check, Continuity check |
Detection method |
True RMS |
Frequency measuring range |
100Hz, 1000Hz, 10kHz, 100kHz, 300kHz |
Frequency measuring accuracy |
±0.1% rdg. ±0.1 Hz, ±0.2% rdg. ±2 dgt. |
Frequency measurement range - Accuracy |
100 Hz - ±0.2% rdg. ±2 dgt., 1000 Hz - ±0.1% rdg. ±1 dgt., 10 kHz - ±0.1% rdg. ±1 dgt., 100 kHz - ±0.1% rdg. ±1 dgt., 300 kHz - ±0.1% rdg. ±1 dgt. |
AC voltage measuring range |
6V, 60V, 600V |
AC voltage measuring accuracy |
±1.5% rdg. ±5 dgt. |
AC voltage measurement range - Accuracy |
6 V - ±1.5% rdg. ±5 dgt. [45...400 Hz], 60 V - ±1.5% rdg. ±5 dgt. [45...400 Hz], 600 V - ±1.5% rdg. ±5 dgt. [45...400 Hz] |
AC current measuring range |
60A, 120A |
AC current measuring accuracy |
±2% rdg. ±5 dgt. |
AC current measurement range - Accuracy |
60 A - ±2% rdg. ±5 dgt. [45...65 Hz], 120 A - ±2.0% rdg. ±5 dgt. [45...65 Hz] |
DC voltage measuring range |
600mV, 6V, 60V, 600V |
DC voltage measuring accuracy |
±1% rdg. ±3 dgt. |
DC voltage measurement range - Accuracy |
600 mV - ±1.0% rdg. ±3 dgt., 6 V - ±1.0% rdg. ±3 dgt., 60 V - ±1.0% rdg. ±3 dgt., 600 V - ±1.0% rdg. ±3 dgt. |
DC current measuring range |
60A, 120A |
DC current measuring accuracy |
±2% rdg. ±5 dgt., ±2% rdg. ±8 dgt. |
DC current measurement range - Accuracy |
60 A - ±2% rdg. ±8 dgt., 120 A - ±2% rdg. ±5 dgt. |
Resistance measuring range |
600Ohm, 6kOhm, 60kOhm, 600KOhm, 6MOhm, 60MOhm |
Resistance measuring accuracy |
±1.0% rdg. ±5 dgt., ±2% rdg. ±5 dgt., ±3% rdg. ±5 dgt. |
Resistance measurement range - Accuracy |
600 Ohm - ±1.0% rdg. ±5 dgt., 6 kOhm - ±1% rdg. ±5 dgt., 60 kOhm - ±1% rdg. ±5 dgt., 600 kOhm - ±1% rdg. ±5 dgt., 6 MOhm - ±2% rdg. ±5 dgt., 60 MOhm - ±3% rdg. ±5 dgt. |
Capacitance measuring range |
4µF, 40µF, 400nF |
Capacitance measuring accuracy |
±2.5% rdg. ±10 dgt. |
Capacitance measurement range - Accuracy |
400 nF - ±2.5% rdg. ±10 dgt., 4 µF - ±2.5% rdg. ±10 dgt., 40 µF - ±2.5% rdg. ±10 dgt. |
Battery requires |
AAA (1.5 V) |
Continuous operating time |
150hours, 25hours |
Test end |
Needle tip, Unique open jaw for current measurements |
Alarm signal type |
Sound |
Function |
Auto power off, Auto hold, Sound alert for Continuity |
Safety rating |
CAT II (600V), CAT III (300V) |
Mounting method |
Hand held |
Connection type |
Test leads |
Operation ambient |
Indoor |
Approx. weight |
220g |
Overall width |
92mm |
Overall height |
128mm |
Overall depth |
27mm |
Representative standard |
CE |
Standard accessories |
Test leads, Open clamp sensor, Battery: R03x2 |
Separately accessories |