Series: Earth leakage circuit breakers (standard class) MITSUBISHI NV32-SV series

Model: NV32-SV 3P 32A 5kA 1.2.500mA

Features of Earth leakage circuit breakers (standard class) MITSUBISHI NV32-SV series (contains model NV32-SV 3P 32A 5kA 1.2.500mA)

Earth leakage circuit breakers (standard class) MITSUBISHI NV32-SV series:
- Number of poles: 3P.
- Rated operational voltage Ue: 100-440 V.
- Current: AC.
- Phase line: 3Φ3W, 1Φ3W, 1Φ2W.
Application: Earth leakage circuit breakers (standard class) MITSUBISHI NV32-SV series are used to switch off electrical circuits when there is an overload, short circuit, protect safety for people and other electrical equipment.

Specifications of Earth leakage circuit breakers (standard class) MITSUBISHI NV32-SV 3P 32A 5kA 1.2.500mA

Type

Earth leakage circuit breaker (ELCB)

Number of poles

3P

Frame size

32AF

Rated current (In)

32A

Line voltage

AC

Rated operational voltage (Ue)

440VAC

Rated frequency

50Hz, 60Hz

Rated residual current

100/200/500mA

Breaking capacity

5kA

Ultimate breaking capacity (Icu)

5kA at 440VAC, 10kA at 230VAC

Service breaking capacity - Ics (% Icu)

100%

Protection delay time

0.1s, 0.04s

Protection function

Ground fault , Overcurrent, Short-circuit

On/Off control type

Handle toggle

Mounting method

Surface mounting

Connection type

Screw terminals

Approx. net weight

750g

Overall width

75mm

Overall height

130mm

Overall depth

90mm

Representative standard

CCC, CE

Standard accessories

Bolts/Screws

Separately accessories

Alarm switch: AL, Auxiliary switch: AX, Earth fault preventing barriers: BAG-05-SV3, F-type operating handle: F-05SV, Handle lock devices (HL): HLF-05SV, Handle lock devices (HL): HLN-05SV, Handle lock devices (LC): LC-05SV, Handle lock devices: HLS-05SV, Insulating Barrier-Front: BAF-05SV, Large terminal covers:TCL-05SV3, Large terminal covers:TCL-05SV3L, Plug-in type terminal block: PM-05SV3, Rear terminal cover: BTC-05SV2, Shunt trip: SHT, Small terminal covers (TC-S): TCS-1SV3, Studs on rear surface: ST-05SV3, Test button module: TBM, Transparent terminal covers: TTC-05SV2, Undervoltage trip: UVT, V-type operating handle: V-05SV, With lead-wrire terninal block: SLT

Document of Earth leakage circuit breakers (standard class) MITSUBISHI

Comment about product
Loading  Processing, please wait ...
Contact us now

 Bao An Automation

Bao An Technique Service Joint Stock Company
Address: 3A Ly Tu Trong, Minh Khai, Hong Bang, Hai Phong, Viet Nam
Haiphong Office and Warehouse: Van Tra B project area, An Dong, An Duong Dist., Haiphong City, Vietnam
Hanoi Office and Warehouse: No. 3/38, Chu Huy Man Str., Phuc Dong Ward, Long Bien Dist., Hanoi City, Vietnam
Ho Chi Minh Office and Warehouse: No. 204, No Trang Long Str., Ward 12, Binh Thanh Dist., Ho Chi Minh City, Vietnam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Hotline: (+84) 989 465 256 (South) / (+84) 936 862 799 (North)
Tax code: 0200682529 - Date: 31/07/2006
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 42 -  Total visited: 120.077.394
Chat hỗ trợ