Earth leakage circuit breakers (standard class) MITSUBISHI  NV63-SV 2P 60A 15kA 30mA

Earth leakage circuit breakers (standard class) MITSUBISHI
1,417,800
2P; 60A; 30mA; 15kA
Manufacturer: MITSUBISHI
Item Status: Contact us
 Customer support hotline for products:
Northern Region, North Central Region:
Southern Region, South Central Region:
 142

Series: Earth leakage circuit breakers (standard class) MITSUBISHI NV63-SV series

Model: NV63-SV 2P 60A 15kA 30mA

Features of Earth leakage circuit breakers (standard class) MITSUBISHI NV63-SV series (contains model NV63-SV 2P 60A 15kA 30mA)

Earth leakage circuit breakers (standard class) MITSUBISHI NV63-SV series:
- Number of poles: 3P.
- Rated operational voltage Ue (AC): 100-440 V.
- Current: AC.
- Phase line: 3Φ3W, 1Φ3W, 1Φ2W.
- Rated impulse withstand voltage Uimp: 6 kV.
Application: Earth leakage circuit breakers (standard class) MITSUBISHI NV63-SV series are the circuit breaker for protection against overload, short circuit, and electrification

Specifications of Earth leakage circuit breakers (standard class) MITSUBISHI NV63-SV 2P 60A 15kA 30mA

Type

Earth leakage circuit breaker (ELCB)

Number of poles

2P

Frame size

63AF

Rated current (In)

60A

Line voltage

AC

Rated operational voltage (Ue)

240VAC

Rated frequency

50Hz, 60Hz

Rated residual current

30mA

Breaking capacity

15kA

Ultimate breaking capacity (Icu)

15kA at 230VAC

Service breaking capacity - Ics (% Icu)

100%

Protection delay time

0.1s, 0.04s

Protection function

Ground fault , Overcurrent, Short-circuit

On/Off control type

Handle toggle

Mounting method

Surface mounting

Connection type

Screw terminals

Approx. net weight

800g

Overall width

75mm

Overall height

130mm

Overall depth

90mm

Representative standard

CCC, CE

Standard accessories

Bolts/Screws

Separately accessories

Alarm switch: AL-05SVLS, Alarm switch: AL-05SVU, Auxiliary switch: AX-05SV, Auxiliary switch: AX-05SVLS, Closed type: NFS-05SV2, Earth fault preventing barriers: BAG-05-SV3, Handle lock devices (HL): HLF-05SV, Handle lock devices (HL): HLN-05SV, Handle lock devices (LC): LC-05SV, Insulating Barrier-Front: BAF-05SV, Large terminal covers:TCL-05SV3L, Mechanical interlock: MI-05SV3, Plug-in terminal cover (PM): PMDN-05SV4H, Round (B-ST): ST05SV2, Round stud (B-ST): ST0SV3, Shunt trip: SHTA240-05SVL, Shunt trip: SHTA240-05SVLS, Shunt trip: SHTA550-05SVL, Shunt trip: SHTA550-05SVLS, Shunt trip: SHTD125-05SVL, Small terminal covers: TCS-05SV2, Test button module: TBM, Undervoltage trip: UVT, Water-proof type: NFW-05SV, With lead-wrire terninal block: SLT

Document of Earth leakage circuit breakers (standard class) MITSUBISHI

Comment about product
Loading  Processing, please wait ...
Contact us now

 Bao An Automation

Bao An Technique Service Joint Stock Company
Address: 3A Ly Tu Trong, Minh Khai, Hong Bang, Hai Phong, Viet Nam
Haiphong Office and Warehouse: Van Tra B project area, An Dong, An Duong Dist., Haiphong City, Vietnam
Hanoi Office and Warehouse: No. 3/38, Chu Huy Man Str., Phuc Dong Ward, Long Bien Dist., Hanoi City, Vietnam
Ho Chi Minh Office and Warehouse: No. 204, No Trang Long Str., Ward 12, Binh Thanh Dist., Ho Chi Minh City, Vietnam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Hotline: (+84) 989 465 256 (South) / (+84) 936 862 799 (North)
Tax code: 0200682529 - Date: 31/07/2006
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 13 -  Total visited: 120.077.429
Chat hỗ trợ