Fan and pump drive LS  LSLV0022H100-4COFN

Fan and pump drive LS
3-phase; 380...480VAC; Applicable motor capacity: 2.2kW (LD); Rated output current: 6A (LD); Max. output frequency: 400Hz; Load: Light duty (LD)
Manufacturer: LS
Item Status: Contact us
 Customer support hotline for products:
Northern Region, North Central Region:
Southern Region, South Central Region:
 729

Series: Fan and pump drive LS H100 series

Model: LSLV0022H100-4COFN

Features of Fan and pump drive LS H100 series (contains model LSLV0022H100-4COFN)

Fan and pump drive LS H100 series:
- Sets the standard for the drive industry.
- Environmentally friendly water treatment.
- Fan and pump systems incorporate for the outstanding energy-saving.

Specifications of Fan and pump drive LS LSLV0022H100-4COFN

Type

Variable Frequency Drives

Application

Fan, Pump

Power supply phases

3-phase

Power supply voltage

380...480VAC

Rated input frequency

50/60Hz

Rated input current

6.5A (LD)

Applicable motor capacity

2.2kW (LD)

Rated output current

6A (LD)

Rated output voltage

380...480VAC

Load

Light duty (LD)

Max. output frequency

400Hz

Overload capacity

120% at 60 s (LD)

Drive designation type

Standard inverter

Keypad

Built-in

Braking unit

Built-in

DC reactor

No

EMC filter

Built-in

Digital inputs

7

Analog inputs

1

Pulse train inputs

1

Transistor outputs

No

Relay outputs

5

Analog outputs

2

Pulse train outputs

1

Control method / control mode

Slip compensation, V/f Control

Function

All auxiliary motor failure trip, Analog input error, ARM short-circuit current trip, Command loss trip, CPU watchdog trip, Damper trip, Drive overload trip, Emergency stop trip, External memory error, Fan trip, IO board connection trip, Keypad command loss trip, Level Detect trip, Low voltage trip, Low voltage trip during operation, Motor overheat trip, Motor overload trip, Motor under-load trip, Option trip, Output open-phase trip, Over-current trip, Overheat trip, Overvoltage trip, Parameter Write trip, Pipe broken trip, Pump clean failure (fault), Temperature sensor trip, Trip caused by external signals

Communication interface

RS485

Communication protocol

Modbus RTU

Connection with PC

USB port

Electric connection method

Screw terminal

Mounting method

Wall-panel mounting

Built-in cooling Fan

Yes

Operation ambient

Standard

Ambient temperature

-10...50°C

Ambient humidity

90% max.

Approx. weight

3.3kg

Overall width

160mm

Overall height

232mm

Overall depth

181mm

Degree of protection

IP20

Representative standard

CE, UL

Standard accessories

No

Separately accessories

No

Document of Fan and pump drive LS

Comment about product
Loading  Processing, please wait ...
Contact us now

 Bao An Automation

Bao An Technique Service Joint Stock Company
Haiphong Office and Warehouse: Van Tra B project area, An Dong, An Duong Dist., Haiphong City, Vietnam
Hanoi Office and Warehouse: No. 3/38, Chu Huy Man Str., Phuc Dong Ward, Long Bien Dist., Hanoi City, Vietnam
Ho Chi Minh Office and Warehouse: No. 204, No Trang Long Str., Ward 12, Binh Thanh Dist., Ho Chi Minh City, Vietnam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Hotline South: (+84)989 465 256
Hotline North: (+84)936 862 799
Tax code: 0200682529 - Date: 31/07/2006
Invoice address: 3A Ly Tu Trong Street, Minh Khai Ward, Hong Bang District, Hai Phong City, Viet Nam
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 642 -  Total visited: 126.936.346
Chat hỗ trợ