Type |
Variable Frequency Drives |
Application |
Conveyor, Crane, Fan, Press, Printing machines, Pump, Shield machines, Unwinder, Winder, Lumber, Metal products manufacturing, Paper manufacturing machines, Pulp, Steel industry, Textile machine, Warehousing, Water transportation, Wood making machine, Construction industry, Forestry |
Power supply phases |
3-phase |
Power supply voltage |
380...500VAC |
Rated input frequency |
50Hz, 60Hz |
Rated input current |
48.2A |
Applicable motor capacity |
18.5kW |
Rated output current |
38A |
Rated output voltage |
380...500VAC |
Max. output frequency |
590Hz |
Drive designation type |
Standard inverter |
Overload capacity at normal duty (60s) |
120% |
Overload capacity at heavy duty (60s) |
150% |
Keypad |
Built-in |
Braking unit |
Built-in |
Braking resistor |
No |
Digital inputs |
12 |
Analog inputs |
1 |
Pulse train inputs |
1 |
Transistor outputs |
6 |
Relay outputs |
2 |
Analog outputs |
2 |
Pulse train outputs |
1 |
Control method / control mode |
High carrier frequency PWM control (V/f. Advanced magnetic flux vector control. real sensorless vector control. optimum excitation control), PM Sensorless vector control, Soft-PWM control, V/f Control, Vector control |
Function |
Inverter overload trip, Motor overheat trip, Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Heatsink overheat, Instantaneous power failure, Brake transistor alarm detection, Input phase loss, Loss of synchronism detection, Output side earth (ground) fault overcurrent, Stall prevention, Undervoltage Protection, Communication option fault, External thermal relay operation, Output phase loss, Output short circuit, PTC thermistor operation, Abnormal output current detection, CPU fault, Operation panel power supply short circuit/RS-485 terminals power supply short circuit, Option fault, Parameter storage device fault, Power fault, PU disconnection, Retry count excess, Analog input fault, Brake sequence fault, Communication fault (inverter), Encoder phase fault, Excessive position fault, Input fault, Inrush current limit circuit fault, Overspeed occurrence, Safety circuit fault, Signal loss detection, Speed deviation excess detection, USB communication fault, Abnormal internal temperature, Internal circuit fault, Magnetic pole position unknown, PID signal fault, Pre-charge fault |
Unique feature/ Function |
Motor control |
Communication interface |
RS485 |
Communication protocol |
CC-link, Modbus RTU, Profibus-DP |
Connection with PC |
RS485 |
Electric connection method |
Screw terminal |
Mounting method |
Wall-panel mounting |
Built-in cooling Fan |
Yes |
Operation ambient |
Indoor |
Ambient temperature |
-10...50°C |
Ambient humidity |
90% max. |
Approx. weight |
15kg |
Overall width |
250mm |
Overall height |
400mm |
Overall depth |
190mm |
Degree of protection |
IP20 |
Representative standard |
CCS, CE, cUL, KC, NK, RoHS, UL |
DC reactor (Sold separately) |
FR-HEL |
Braking unit (Sold separately) |
FR-BU2 |
Braking resistor (Sold separately) |
FR-ABR |