Type |
Safety light curtains / safety light barriers / safety multi-light beams |
Sensing method |
Through-beam (Full set) |
Max. sensing distance |
16m |
Protective height |
1360mm |
Number of optical axis |
68 |
Optical axis pitch |
20mm |
Dimension of standard sensing object |
D25mm |
Standard sensing object |
Opaque |
Power supply voltage |
24VDC |
Input type |
NPN, PNP |
Input functions |
Muting input A, Muting input B, Reset input, Test input (External test) |
Output type |
NPN, PNP |
Operation mode |
Light On |
Light source (wavelength) |
Infrared LED (870 nm) |
Response time |
13ms, 17ms, 26ms, 34ms, 52ms, 68ms, 85ms, 90ms, 104ms, 130ms, 136ms, 170ms, 260ms, 340ms, 520ms, 680ms |
Function |
Cascade connection, , Fixed blanking, Interlock (Reset hold), , Mutual interference prevention, PNP/NPN selection, , Floating blanking, Reduced resolution, Response time adjustment, Self-test (Test function) |
Safety standards |
Performance level (PL)/ safety category: PL c/category 2, |
Communication |
No |
Case material |
Aluminum alloy |
Connection method |
Pre-wire |
Cable length |
15m |
Mounting method |
Backside mounting, Side-mount bracket |
Operation ambient |
Oil-resistance |
Ambient illumination |
Sunlight: 10,000 Ix max. |
Ambient temperature |
-30...55°C |
Ambient humidity |
35...85% |
Approx. net weight |
11.4kg |
Overall width |
82mm |
Overall height |
1560mm |
Overall depth |
70mm |
Degree of protection |
IP69K |
Representative standard |
CE, TUV, UL |
Standard accessories |
No |
Separately accessories |
Bracket: F39-LSGTB-K, Floor mount column: F39-ST0990, Intelligent tap: F39-SGBT, Intelligent tap: F39-SGIT-IL3, Lamp: F39-SGLP, Mount-column adjustable base: F39-STB, Muting sensor arm mounter: F39-FMA150R, Muting sensor connection box: F39-GCN5 |