- Applicable standard: TCVN 5935 : 1995/ IEC 60502-1:2009; IEC 60502-2:2005
- Conductor: Aluminum or Copper
- Number of cores: single or multi-core
- Structure: Twisted by multi-core hard cores (aluminum) or annealed cores (copper)
- Material: XLPE/PVC
- Working temperature of conductor: 70°C; 90°C
- Nominal cross-section:
+ Copper conductor from 7.5 mm2 to 1000 mm2
+ Aluminium conductor from 10 mm2 to 1000 mm2
- Nominal rated voltage from 0.6/1 kV to 18/30 kV

General specifications of XLPE insulated PVC sheathed 4-cores copper cable CADISUN CXV 4x series

Type

Electrical cables

Application type

Motors, Power supply

Number of cores

4

Conductor nominal cross section (sqmm)

1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm²

Number of cores and conductor nominal cross section (sqmm)

4x1.5mm², 4x2.5mm², 4x4mm², 4x6mm², 4x10mm², 4x16mm², 4x25mm², 4x35mm², 4x50mm², 4x70mm², 4x95mm², 4x120mm², 4x150mm², 4x185mm², 4x240mm², 4x300mm², 4x400mm²

Voltage level

Low voltage cables

Rated voltage

0.6/1KV

Conductor material

CU

Conductor classification

Stranded

Wire finish

Insulation

Shield structure

Unshielded

Filler

Yes

Inner insulation material

XLPE

Outer insulation material

PVC

Outer insulation color

Black

Core difference

By color

Flexibility

Flexible

Cable/wire outer diameter

12.2mm, 13.1mm, 14.6mm, 16.1mm, 175mm, 19.9mm, 23.3mm, 26.2mm, 29.6mm, 34.7mm, 39mm, 42.8mm, 48.1mm, 53.1mm, 60.1mm, 66mm, 74.4mm

Cable/wire length

Made to order

Conductor structure (No./mm)

7/0.52, 7/0.67, 7/0.85, 7/1.04, 19/, 37/, 61/

Max. DC resistance of conductor at 20°C (ohm/km)

12.1, 7.41, 4.61, 3.08, 1.83, 1.15, 0.727, 0.524, 0.387, 0.268, 0.193, 0.153, 0.124, 0.0991, 0.0754, 0.0601, 0.0470

Operation ambience

Standard

Approx. weight per metter

0.1918kg, 0.2429kg, 0.3281kg, 0.4274kg, 0.5907kg, 0.8429kg, 1.2468kg, 1.6551kg, 2.1969kg, 3.0753kg, 4.1419kg, 5.1461kg, 6.3738kg, 7.8777kg, 10.2382kg, 12.6975kg, 16.3426kg

Overall diameter

12.2mm, 13.1mm, 14.6mm, 16.1mm, 175mm, 19.9mm, 23.3mm, 26.2mm, 29.6mm, 34.7mm, 39mm, 42.8mm, 48.1mm, 53.1mm, 60.1mm, 66mm, 74.4mm

Overall length

Made to order

Representative standard

IEC 60502-1, TCVN 5935-1

Document of XLPE insulated PVC sheathed 4-cores copper cable CADISUN CXV 4x series

Comment about product
Loading  Processing, please wait ...
Contact us now

 Bao An Automation

Bao An Technique Service Joint Stock Company
Address: 3A Ly Tu Trong, Minh Khai, Hong Bang, Hai Phong, Viet Nam
Office 1: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Office 2: 3/38, Chu Huy Man, Phuc Dong, Long Bien, Ha Noi, Viet Nam
Factory: Van Tra B project area, An Dong, An Duong, Hai Phong, Viet Nam
Phone: (+84) 2253 79 78 79, Hotline: (+84) 989 465 256
Tax code: 0200682529 - Date: 31/07/2006
 Designed by Bao An Technique Service Joint Stock Company
 Email: baoan@baoanjsc.com.vn -  Curent online: 26 -  Total visited: 101.175.865
Chat hỗ trợ