Series Name | Product Name∗1 | Discontinuation Date |
Service Supply End Date (for Parts)∗2 |
Repairs End Date∗2 |
Recommended Replacements |
---|---|---|---|---|---|
CPCR | CPCR-MR08CΔ ··· to CPCR-MR99CΔ ··· |
8/20/2009 | - | 8/20/2019 | Σ-7 Series∗3 |
CPCR | CPCR-MR01DΔ ··· to CPCR-MR07DΔ ··· |
8/20/2009 | - | 8/20/2019 | Σ-7 Series∗3 |
CPCR | CPCR-FR□ | 3/20/2007 | 3/20/2012 | 3/20/2017 | Σ-7 Series∗3 |
CPCR | CPCR-IN□□Δ … , CPCR-SW□□Δ … , CPCR-SF□□Δ … , CPCR-PF□□Δ … |
3/20/2005 | 3/20/2010 | 3/20/2015 | Σ-7 Series∗3 |
CPCR | DC mechanical feed | 9/21/2000 | 9/20/2001 | 3/20/2006 | Combinations of MP Series of controllers and Σ-7 Series∗3 |
CPCR | CPCR-AN□□Δ … | 9/21/2000 | 9/20/2001 | 3/20/2006 | Σ-7 Series∗3 |
CPCR | CPCR-MR01CΔ … to CPCR-MR07CΔ … |
8/29/2000 | - | - | Σ-7 Series∗3 |
* 1: □: Công suất Δ ···: Các thông tin khác như điện áp
* 2: Các thành phần bảo trì có thể không có ngay cả trước khi thời gian hết hạn vì các yếu tố bên ngoài như sự sẵn có của các thành phần và tiêu thụ của các dự trữ chứng khoán.
* 3: Nếu các đặc điểm kỹ thuật không phù hợp, xin vui lòng sử dụng Σ-V Series.
Series Name | Product Name∗1 | Discontinuation Date |
Service Supply End Date (for Parts)∗4 |
Repairs End Date∗4 |
Recommended Replacements |
---|---|---|---|---|---|
Σ-III Series | SGDS | 3/20/2015 | 9/20/2014 (No more orders to be accepted after this date.) |
3/20/2025 | Σ-7 Series∗5 |
Σ-II Series |
SGDM, SGDH, SGDP, SGDJ, SGDD, JUSP-NS100, JUSP-NS110, JUSP-NS115, JUSP-NS300, JUSP-NS310, JUSP-NS500, JUSP-NS600, JUSP-NJ001, JUSP-HS001, JUSP-FC100, JUSP-LD001, JUSP-COV03 |
3/20/2015 | 9/20/2014 (No more orders to be accepted after this date.) |
3/20/2025 | Σ-7 Series∗5 |
Σ-mini Series | SGDF-A1CΔ, SGDF-A2CΔ, SGDF-A3CΔ, SGDF-B3CΔ, SGDF-B5CΔ, SGDF-B9CΔ |
5/20/2013 | 3/20/2013 (No more orders to be accepted after this date.) |
5/20/2023 | Σ-V mini Series |
Σ Series | SGD-□□AH, SGD-□□VH, SGD-□□BH, SGD-□□WH, SGD-□□AN, SGD-□□VN, SGD-□□BN, SGD-□□WN |
11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ Series | SGDA-□□AS, SGDA-□□VS, SGDA-□□BS, SGDA-□□WS, SGDA-□□BSM, SGDA-□□CS, SGDA-□□AP, SGDA-□□VP, SGDA-□□BP, SGDA-□□WP, SGDA-□□BPM |
11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ Series | SGDB-□□AD, SGDB-□□VD, SGDB-□□DD, SGDB-□□AN, SGDB-□□AM |
11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ Series | SGDC-□□DSA | 11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ Series | SGDE-□□AS, SGDE-□□VS, SGDE-□□BS, SGDE-□□WS, SGDE-□□AP, SGDE-□□VP, SGDE-□□BP, SGDE-□□WP |
11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ Series | SGDL-□□AS, SGDL-□□BS, SGDL-□□AP, SGDL-□□BP |
11/20/2008 | 9/20/2008 (No more orders to be accepted after this date.) |
11/20/2018 | Σ-7 Series∗5 |
Σ-II Series | JUSP-NS300, JUSP-NS500 |
3/20/2007 | 3/20/2007 | 3/20/2012 | JUSP-NS∗∗∗-∗-E (RoHS-compliant) |
Σ Series | DR2-□□AC, DR2-□□BC, DR2-□□ACP, DR2-□□BCP, DR2-□□AC-F, DR2-□□BC-F, DR2-□□ACP-F, DR2-□□BCP-F, DR2-□□AD, DR2-□□BD |
12/20/2006 | 6/20/2008 | 12/20/2016 | Σ-7 Series∗5 |
CACR-HR | CACR-HR□□BAB, CACR-HR□□BB, CACR-HR□□BBC, CACR-HR□□SB, CACR-HR□□SBC, CACR-HR□□CB |
9/20/2004 | 9/20/2009 | 9/20/2014 | Σ-7 Series∗5 |
Σ-II Series | SGDM-□□AD, SGDM-□□BD |
3/20/2004 | 3/20/2009 | 3/20/2014 | Replace with motors that are equivalent to motors in theΣ-7 Series*5, SGDM-□□ADA, or SGDM-□□□BDA. |
CACR-HR | CACR-HR□□AAB, CACR-HR□□AB |
3/20/2003 | 3/20/2008 | 3/20/2013 | Σ-7 Series∗5 |
Large- capacity Servo (VS-866) |
CIMR-SVJ□□ | 9/21/2002 | 9/20/2007 | 9/20/2012 | Large-capacity Σ-II Series |
CACR-HR | CACR-HR□□UB, CACR-HR□□VBC |
6/20/2001 | 6/20/2006 | 6/20/2011 | Σ-7 Series∗5 |
CACR-SR | CACR-SR□□BB, CACR-SR□□BC, CACR-SR□□BD, CACR-SR□□BE, CACR-SR□□BY, CACR-SR□□BZ, CACR-SR□□SB, CACR-SR□□SZ, CACR-SR□□TB, CACR-SR□□TZ, CACR-SR□□UB, CACR-SR□□VE |
9/21/2000 | 8/6/2002 | 3/20/2007 | Σ-7 Series∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
CACR-PR | CACR-PR□□BB, CACR-PR□□BC, CACR-PR□□AD |
9/21/2000 | 8/6/2002 | 3/20/2007 | Σ-7 Series ∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
CACR-DR | CACR-DR□□BA, CACR-DR□□BZ |
9/21/2000 | 8/6/2002 | 3/20/2007 | Σ-7 Series∗5 |
Σ Series | DR1-□□AC, DR1-□□BC, DR1-□□AA, DR1-□□BA |
6/21/1998 | 6/20/2003 | 6/20/2008 | Σ-7 Series ∗5 |
Σ Series | SGD-□□AS, SGD-□□BS, SGD-□□AP, SGD-□□BP |
6/21/1998 | 6/20/2003 | 6/20/2008 | Σ-7 Series ∗5 |
CACR-SR | CACR-SR□□AB, CACR-SR□□AC, CACR-SR□□AD, CACR-SR□□AH, CACR-SR□□AX, CACR-SR□□AY, CACR-SR□□AZ, CACR-SR□□KA |
5/21/1996 | 5/20/1999 | 5/20/2003 | Σ-7 Series ∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
CACR-PR | CACR-PR□□AC, CACR-PR□□AE, CACR-PR□□AH, CACR-PR□□KA |
5/21/1996 | 5/20/1999 | 5/20/2003 | Σ-7 Series ∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
CACR-SR | CACR-SR□□AA∗2, CACR-SR□□BA∗2 |
2/20/1995 | 3/20/1996 | 9/20/1999 | Σ-7 Series∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
CACR-PR | CACR-PR□□AA∗2, CACR-PR□□BA∗2 |
2/20/1995 | 3/20/1996 | 9/20/1999 | Σ-7 Series ∗5or replaced products by YASKAWA Electric Engineering Corporation∗3 |
* 1: □: Công suất Δ ···: Các thông tin khác như điện áp
* 2: JUSP-ACP ** AA cũng là ngưng
* 3: Liên hệ với đại lý hàng của Yaskawa cho các sản phẩm thay thế
* 4: Các thành phần bảo trì có thể không có ngay cả trước khi thời gian hết hạn
* 5: Nếu các đặc điểm kỹ thuật không phù hợp, xin vui lòng sử dụng Σ-V Series
Series Name | Product Name∗1 | Discontinuation Date |
Service Supply End Date (for Parts)∗2 |
Repairs End Date∗2 |
Recommended Replacements |
---|---|---|---|---|---|
Serial Converter Unit | JZDP-AΔΔΔ, JZDP-CΔΔΔ |
3/20/2006 | 3/20/2011 | 3/20/2016 | D Type |